Beamex MC6-Ex Intrinsically Safe Advanced Field Calibrator and Communicator
Key capabilities
| Function | Capability |
|---|---|
| Electrical measurement | Voltage ±500 mV / ±30 VDC; current ±100 mA |
| Electrical generation | Voltage ±500 mV and −1.5 to 10.5 VDC; current 0–25 mA |
| Resistance | Measurement and simulation, 0–4 kΩ |
| RTD | Measurement and simulation |
| Thermocouple | Measurement and simulation |
| Frequency | Measurement 0–50 kHz; generation 0–10 kHz |
| Pulse | Counting/generation up to 10 Mpulse |
| Pressure | Internal/external pressure modules |
| Loop supply | Built-in |
| Communications | HART, FOUNDATION Fieldbus, PROFIBUS PA |
| Switch testing | Dry/wet switch sensing |
Some functions are optional depending on configuration.
Five operating modes
The MC6-Ex essentially combines several instruments into one handheld unit:
- Meter – measurement and signal monitoring
- Calibrator – measurement, sourcing and simulation
- Documenting calibrator – guided calibration with results recording
- Data logger – recording measurements over time
- Fieldbus communicator – configuration, trimming and communication with smart instruments
Intrinsic-safety certification
This is one of the MC6-Ex’s main differentiators. Its certifications include:
- ATEX: II 1 G, Ex ia IIC T4 Ga
- IECEx: Ex ia IIC T4 Ga
- North America: Class I, Zone 0, AEx ia IIC T4 Ga; Class I, Division 1, Groups A–D, T4
- Ambient temperature: −10 to +50 °C
- IP65 enclosure
- 1 m drop-test rating
The safety documentation specifies that the MC6-Ex must use its approved RB-796-Ex rechargeable battery pack, and battery charging must be performed outside hazardous areas using the specified Beamex charger.
Physical specifications
- Display: 5.7-inch, 640 × 480 TFT LCD
- Touchscreen: 5-wire resistive
- Keyboard: membrane type
- Dimensions: 207 × 231 × 80 mm
- Weight: approximately 2.5–2.9 kg
- Battery: 9.6 V, 4200 mAh NiMH
- Battery operation: approximately 4–8 hours
- Charging time: approximately 10 hours
- Operating temperature: −10 to +50 °C
Calibration workflow
A particularly useful feature is the documenting calibration capability. The MC6-Ex can guide the technician through calibration procedures, calculate errors and pass/fail results, and transfer calibration information to Beamex calibration-management software. This supports a paperless calibration workflow.
It is therefore suited to applications such as oil & gas, petrochemical, chemical processing, pharmaceutical and other process plants where instrumentation must be calibrated in potentially explosive areas.
Official product page: Beamex MC6-Ex
Bottom line: The MC6-Ex is essentially an Ex-rated multifunction process calibrator + documenting calibrator + data logger + HART/Fieldbus communicator in one instrument, aimed at technicians who need to perform instrumentation calibration directly in hazardous areas.